Details
Descaling agent

.
Main uses
Mainly used in industrial and living power stations, boilers, sewage treatment, circulation pipes, condensers, central air conditioners, deep well pumps, heating jackets and other equipment to remove carbon from the operation. Removal of salt scale, iron rust scale.
2
.
Performance features
Easy to operate
No clogging
Saving time
Saving costs
Easy to operate and using existing equipment and technicians can operate it.
No clogging. During the cleaning process, the chemical reaction between the liquid and the scale will cause the scale to dissolve into the liquid, without causing flakes to fall off and causing clogging.
The fastest time saving takes only a few hours at most
hours.
The cost savings is
more than other cleaning costs.
The corrosion rate is low, and the cleaning and corrosion retardation rate for ferrous metals and non-ferrous metals is above
.
Three
.
Product indicators

Model
No.
Descaler
Descaler

Appearance
Appearance
White solid
Reddish liquid

Density
/
Filling
.
~
.


H
Value

(
Aqueous solution)


Water-insoluble matter
%



Scale removal rate (carbonate scale)



Slow Corrosion rate



Dissolution rate



4. How to use
(1) Dosage
Descaling agent
The dosage is
~
calculated according to the volume of the cleaning part (added per cubic meter of water
~< br/>).
Descaling agent
Stock solution
Dilute and use.
During cleaning
H
The value remains around
~
.
If the
H
value does not reach
~
.
You should continue to add chemicals.
(2) Usage method
Using temperature water temperature



Not greater than

The cleaning time is generally
~
It can be increased or decreased appropriately according to the scaling situation in about 2 hours.
When cleaning the equipment, open the air vents to prevent air blockage.
If the
H
value of the chemical solution has been around
~
.
during the cleaning process, it means that the descaling has ended.
Drain the cleaning fluid after cleaning. Then flush the pipes one by one with water to check whether there is any blockage. If there is an original blockage, use manual or pipe dredging machine to clear it to ensure that each pipe is unblocked and the equipment can operate normally.
5. Precautions
When cleaning, if the liquid comes into contact with the skin, just rinse with clean water.
After cleaning, when the equipment is running normally again, you can add the anti-scaling and anti-scaling agent produced by our company according to the concentration of
.
~
. This product can inhibit scale and scale. Function